The PosiTector SST Soluble Salt Tester measures the concentration of soluble salts (salt contamination) on metal surfaces in accordance with ISO 8502-6, 8502-9. The large, easy-to-read color LCD displays test duration, sample temperature, conductivity (µS/cm) and surface density (mg/m2 or µg/cm2). Easy 1-2-3 gage interface guides users through the Bresle test method.
The probe can be swapped out with any other PosiTector probe allowing the device to act as several different measuring instruments including but not limited to a dew point meter, a thermometer, a surface profiler, and a thickness gauge. See related products for a more inclusive list.
Easy-To-Use
- Conductivity probe specifically designed for ISO 8502-6,9
- Displays test duration, sample temperature, conductivity (µS/cm) and surface density (mg/m2 or µg/cm2)
- Easy 1-2-3 gage interface guides users through the Bresle test method
- Automatic storage of a background (blank) measurement - handy when performing multiple tests
Durable
- Solvent, acid, oil, water and dust resistant - weatherproof
- Shock-absorbing, protective rubber holster with belt clip
- Two year warranty on body AND probe
Accurate
- Long Form Certificate of Calibration showing traceability to NIST included
- Includes certified conductivity standard (calibration solution) to verify probe accuracy. Certificate included.
- Automatic temperature normalization and sample temperature reporting
- Conforms to national and international standards including ISO, NACE, SSPC, IMO and US Navy
Versatile
- PosiTector body accepts all PosiTector SST, 6000, 200, SPG, RTR, DPM, SHD and UTG probes easily converting from a soluble salt tester to a coating thickness gage, surface profile gage, dew point meter, shore hardness durometer or ultrasonic wall thickness gage
- Ideal for determination of water-soluble contaminants in non-metallic blast media
- A selection of kits include everything needed to retrieve and analyze soluble salts on surfaces
- Adjustable for various patch volumes
- Selectable Display Languages: English, French, German, Spanish, Japanese, Chinese, Korean, Dutch, Portuguese, Italian, Norwegian, Russian, Czech, Polish and Turkish.
- High contrast, reversible color LCD with backlit display
- Uses alkaline or rechargeable batteries (built-in charger)
Powerful
- Tracks test duration in accordance with ISO 8502-6
- Screen Capture – save screen images for record keeping and review
- USB port for fast, simple connection to a PC and to supply continuous power
- Every measurement is date and time stamped
- Software updates via the internet keep your gage current
- Stored readings and graphs can be accessed using universal PC/Mac web browsers or file explorers. No software required
Feature Comparison Chart | Basic (1) | Memory (3) |
---|---|---|
Hi Contrast LCD Display | Standard Display |
Advanced Display |
Reading Storage Capacity | 250 in one group | 100,000 in up to 1000 groups |
Batch annotation—add notes and change batch names with onscreen QWERTY keyboard | - | |
WiFi technology wirelessly synchronizes downloads software updates | - | |
Data transfer via USB to a PC or via Bluetooth Wireless Technology to a mobile device, PC or printer | - | |
Store thickness, profile, environmental, wall thickness, hardness and salt contamination measurements in individual batches | - |
PosiPatch
Reusable flexible patch with magnetic ring
For measuring salt contamination in accordance with ISO 8502-6,9
*Flexible magnetic ring minimum ID is 12 cm (4.5 in.)
-
Magnetic ring attaches to steel with no residue to clean
- Standard magnetic ring for flat surfaces and diameters > 1m (40 in.)
- Flexible magnetic ring for ID/OD diameters > 10 cm (4 in.)*
- Automatic air removal through a watertight, air permeable membrane
- No sharps, no needles! Safe, flexible dispensing tip mates with PosiPatch
- Comparable price to latex patches
- Reusable patent-pending PosiPatch saves time and money
- Easy-to-use in any orientation
Test Area | 1250 mm2 |
Test Volume | 2.5 - 3 ml |
Patch Diameter | 44.4 mm (1.75 in) |
Magnetic Ring Diameter | 66.9 mm (2.60 in) |
Background Contamination | < 3 mg/m2 |
Polyurethane Adhesive Patch
Self-adhesive, polyurethane patches
For measuring salt contamination in accordance with ISO 8502-6,9
- Low-tack adhesive for easy patch removal with no residue to clean
- Works on nearly any material or surface geometry
- Latex-free
- Lower cost than latex patch
- Easy-to-use in any orientation
Test Area | 1250 mm2 |
Test Volume | 2 - 3 ml |
Dimensions | 50 mm x 50 mm (1.97 in x 1.97 in) |
Background Contamination | < 5 mg/m2 |
Latex Adhesive Patch
ISO 8502-6 conforming latex patch with easy-open tab and low-tack adhesive with TearGuard™ technology.Range | 0 - 500 µS/cm, 0 - 2000 mg/m2, 0.0 - 200.0 µg/cm2 |
Resolution* | 1 µS/cm, 1 mg/m2, 0.1 µg/cm2 |
Accuracy | ± 2 µS/cm (0 - 200 µS/cm) ± 10 µS/cm (201 - 500 µS/cm) |
Temperature Range | 0 - 50°C |
Normalization Temperature | 25°C (77°F) |
Test Cell Volume | 1 ml |
Dimensions | 165 x 61 x 28 mm (6.5" X 2.4" X 1.1") |
Weight | 140 g (4.9 oz) without batteries |
Conforms to | ISO 8502-6/8502-9, US Navy NSI 009-32, US Navy PPI 63101-000, AS 3894.6, IMO MSC.215(82), IMO MSC.244(83), SSPC Guide 15, ISO 11127-6, ASTM D4940 |
* Hi Res Mode 0.1 µS/cm (0 - 200 µS/cm)
Why is salt contamination measurement important?
The presence of soluble salts has been shown to have a significant negative effect on coating performance and leads to premature coating failure. Salts remaining beneath a protective coating create an osmotic force that draws water from the atmosphere through the paint layer. The pressure created by this water underneath the coating overcomes the adhesive bond between the coating and substrate, resulting in corrosion, osmotic blistering and eventual coating failure. It is therefore critical to ensure that a substrate is free from soluble salt contamination before painting.
What is measured with the PosiTector SST?
The PosiTector SST includes a certified and traceable conductivity probe specifically designed for ISO 8502-6,9. Included with each probe is a Long Form Certificate of Calibration. The following parameters are measured by the PosiTector SST:
-Conductivity (µS/cm)
-Sampling Temperature (C° or F°) normalized to 25°C
-Test duration
Using the measured conductivity value and the sample test volume (set within the gage menu), the surface density of the salts (mg/m2 or µg/cm2) is automatically calculated in accordance with ISO 8502-9, saving the gage operator time and eliminating the chance of a calculation error.
What are some typical applications?
The PosiTector SST is ideal for:
(a) Testing substrates for the presence of soluble salts in accordance with ISO 8502-6,9 (the Bresle Method)
(b) Testing blast media in accordance with ASTM 4940 and ISO 11127-6 (determination of water-soluble contaminates in abrasives by conductivity measurement)
(c) Testing the conductivity of water within the range of 0-500 µS/cm
How is the PosiTector SST conductivity probe different than the conventional conductivity meters included with most other test kits?
The PosiTector SST conductivity probe is specifically designed for ISO 8502-6,9 and has a number of features not found in conventional conductivity meters including . . .
-An onscreen user interface to walk users through the Bresle test method, simplifying the task
-Tracking and reporting of test duration (the total time of contact between the solvent and substrate) as required by ISO 8502-6
-Automatic calculation of surface density with adjustments for different patch volumes – works with ANY Bresle-type patch
-Free software for viewing and reporting data
-Long form certificate of calibration traceable to NIST included at no extra charge. A certificate also comes with the included conductivity standard (calibration solution).
-Automatic 25°C temperature normalization
-Sample temperature recording as required by ISO 8502-9
-Purpose-built, 1 ml test cell is optimized for the range, resolution and test volume of the Bresle Method
-Rugged, stainless steel electrodes – ideal for industrial environments
-Two year warranty
What information does the PosiTector SST save in its memory for each test?
The PosiTector SST saves all measured information for each test. All information is also reported in PosiSoft software.
-Date and time of test
-Test duration (the total time of contact between the solvent and substrate)
-Background sample temperature (°C or °F)
-Final sample temperature (°C or °F)
-Increase in conductivity between background and final sample (µS/cm)
-Calculated surface density of soluble salts (mg NaCl/m2, mg CL/m2, µg NaCl/cm2, or µg Cl/cm2)
Do your instruments require any formal training for use? Do you offer ‘demo’ models?
No. Our instruments are designed for simple operation, feature easy-to-use menus, both full and quick instruction manuals, and helpful videos. In lieu of demonstration models, we provide unlimited technical support via telephone and/or email, and a limited 30-day money back guarantee.
Does the PosiTector SST need to be calibrated prior to use?
The PosiTector SST arrives fully calibrated and ready to measure. A Long-Form Certificate of Calibration traceable to NIST or PTB is included, which documents actual readings taken by your instrument at our calibration laboratory on standards traceable to a national metrology institute. Beware of ‘Certificates’ or ‘Certificates of Conformance’ offered by competitors. These typically do not include actual instrument readings, and are often insufficient to meet common quality requirements.
A Verification of Accuracy can be performed by the user by measuring known reference standards such as the supplied conductivity standard.
Does the PosiTector SST measure the concentration of individual salt ions?
The PosiTector SST measures the overall conductivity of the test solution, and using calculations specified in ISO 8502-9, converts this value into a total surface density of salts.
Does the PosiTector SST display readings in PPM of salt?
The PosiTector SST is built specifically for the Bresle test method which does not address PPM calculations. While empirical conversion factors exist for converting PPM to surface density, these are not recognized by any test method.
Can the PosiTector SST probe be immersed in the fluid it is testing?
Yes. By immersing only the test cell, the PosiTector SST is ideal for testing the conductivity of water within the range of 0-500 µS/cm.
Can the PosiTector SST be used to measure the salt concentration in blast media?
Yes. The PosiTector SST can be used as a conventional conductivity meter making it ideal for testing abrasive materials in accordance with ISO 11127-6 and ASTM D4940-15.
How often should the PosiTector probe be recalibrated? PosiTector probes include a Certificate of Calibration with no expiry or end date. They have no shelf life, therefore the length of time in the field is not a good indicator for recalibration intervals. Many organizations with quality programs and recertification programs require annual recalibrations, and this is a good starting point for most users. Manufacturers recommend that customers establish calibration intervals based upon their own experience and work environment. Based on our product knowledge, data and customer feedback, a one year calibration interval from the date the instrument was placed in service is a good starting point.
The presence of soluble salts has been shown to have a significant negative effect on coating performance and leads to premature coating failure. Salts remaining beneath a protective coating create an osmotic force that draws water from the atmosphere through the paint layer. The pressure created by this water underneath the coating overcomes the adhesive bond between the coating and substrate, resulting in corrosion, osmotic blistering and eventual coating failure. It is therefore critical to ensure that a substrate is free from soluble salt contamination before painting.
What is measured with the PosiTector SST?
The PosiTector SST includes a certified and traceable conductivity probe specifically designed for ISO 8502-6,9. Included with each probe is a Long Form Certificate of Calibration. The following parameters are measured by the PosiTector SST:
-Conductivity (µS/cm)
-Sampling Temperature (C° or F°) normalized to 25°C
-Test duration
Using the measured conductivity value and the sample test volume (set within the gage menu), the surface density of the salts (mg/m2 or µg/cm2) is automatically calculated in accordance with ISO 8502-9, saving the gage operator time and eliminating the chance of a calculation error.
What are some typical applications?
The PosiTector SST is ideal for:
(a) Testing substrates for the presence of soluble salts in accordance with ISO 8502-6,9 (the Bresle Method)
(b) Testing blast media in accordance with ASTM 4940 and ISO 11127-6 (determination of water-soluble contaminates in abrasives by conductivity measurement)
(c) Testing the conductivity of water within the range of 0-500 µS/cm
How is the PosiTector SST conductivity probe different than the conventional conductivity meters included with most other test kits?
The PosiTector SST conductivity probe is specifically designed for ISO 8502-6,9 and has a number of features not found in conventional conductivity meters including . . .
-An onscreen user interface to walk users through the Bresle test method, simplifying the task
-Tracking and reporting of test duration (the total time of contact between the solvent and substrate) as required by ISO 8502-6
-Automatic calculation of surface density with adjustments for different patch volumes – works with ANY Bresle-type patch
-Free software for viewing and reporting data
-Long form certificate of calibration traceable to NIST included at no extra charge. A certificate also comes with the included conductivity standard (calibration solution).
-Automatic 25°C temperature normalization
-Sample temperature recording as required by ISO 8502-9
-Purpose-built, 1 ml test cell is optimized for the range, resolution and test volume of the Bresle Method
-Rugged, stainless steel electrodes – ideal for industrial environments
-Two year warranty
What information does the PosiTector SST save in its memory for each test?
The PosiTector SST saves all measured information for each test. All information is also reported in PosiSoft software.
-Date and time of test
-Test duration (the total time of contact between the solvent and substrate)
-Background sample temperature (°C or °F)
-Final sample temperature (°C or °F)
-Increase in conductivity between background and final sample (µS/cm)
-Calculated surface density of soluble salts (mg NaCl/m2, mg CL/m2, µg NaCl/cm2, or µg Cl/cm2)
Do your instruments require any formal training for use? Do you offer ‘demo’ models?
No. Our instruments are designed for simple operation, feature easy-to-use menus, both full and quick instruction manuals, and helpful videos. In lieu of demonstration models, we provide unlimited technical support via telephone and/or email, and a limited 30-day money back guarantee.
Does the PosiTector SST need to be calibrated prior to use?
The PosiTector SST arrives fully calibrated and ready to measure. A Long-Form Certificate of Calibration traceable to NIST or PTB is included, which documents actual readings taken by your instrument at our calibration laboratory on standards traceable to a national metrology institute. Beware of ‘Certificates’ or ‘Certificates of Conformance’ offered by competitors. These typically do not include actual instrument readings, and are often insufficient to meet common quality requirements.
A Verification of Accuracy can be performed by the user by measuring known reference standards such as the supplied conductivity standard.
Does the PosiTector SST measure the concentration of individual salt ions?
The PosiTector SST measures the overall conductivity of the test solution, and using calculations specified in ISO 8502-9, converts this value into a total surface density of salts.
Does the PosiTector SST display readings in PPM of salt?
The PosiTector SST is built specifically for the Bresle test method which does not address PPM calculations. While empirical conversion factors exist for converting PPM to surface density, these are not recognized by any test method.
Can the PosiTector SST probe be immersed in the fluid it is testing?
Yes. By immersing only the test cell, the PosiTector SST is ideal for testing the conductivity of water within the range of 0-500 µS/cm.
Can the PosiTector SST be used to measure the salt concentration in blast media?
Yes. The PosiTector SST can be used as a conventional conductivity meter making it ideal for testing abrasive materials in accordance with ISO 11127-6 and ASTM D4940-15.
How often should the PosiTector probe be recalibrated? PosiTector probes include a Certificate of Calibration with no expiry or end date. They have no shelf life, therefore the length of time in the field is not a good indicator for recalibration intervals. Many organizations with quality programs and recertification programs require annual recalibrations, and this is a good starting point for most users. Manufacturers recommend that customers establish calibration intervals based upon their own experience and work environment. Based on our product knowledge, data and customer feedback, a one year calibration interval from the date the instrument was placed in service is a good starting point.
Gauge/Probe Only | Kit P | Kit D | Kit L | |
---|---|---|---|---|
Probe Only1 | PRBSST | SSTKITP | SSTKITD | SSTKITL |
Standard Body + Probe2 | SST1 | SSTKITP1 | SSTKITD1 | SSTKITL1 |
Advanced Body + Probe2 | SST3 | SSTKITP3 | SSTKITD3 | SSTKITL3 |
Inclusions |
|
|
|
|
1 PosiTector SST Probe Only models come complete with: certified conductivity standard, foam swabs (5), Long Form Certificate of Calibration traceable to NIST, instructions, PosiSoft Software, two (2) year warranty. 2 PosiTector SST Standard/Advanced Body + Probe models come complete with: protective rubber holster, certified conductivity standard, foam swabs (5), Long Form Certificate of Calibration traceable to NIST, belt clip, wrist strap, 3 AAA alkaline batteries, instructions, protective lens shield, USB cable, PosiSoft Software, two (2) year warranty |
Item | Description | Price | ||
---|---|---|---|---|
SSTKITD | Soluble Salt Tester Polyurethane Patch Kit - Probe Only - SSTKITD-E | $675.00 | ||
Accessories | ||||
SSTKITPATCHP | PosiPatch Starter Kit | $300.00 | ||
SSTKITPATCHPF | PosiPatch Starter Kit with Flexible Ring | $300.00 | ||
SSTPATCHP24 | PosiPatches (24) | $275.00 | ||
SSTPATCHP5 | PosiPatches (5) | $90.00 | ||
SSTPATCHD25 | Polyurethane Patches (25) | $95.00 | ||
SSTPATCHL25 | Latex Patches (25) | $145.00 | ||
SSTRING | PosiPatch Magnetic Ring | $195.00 | ||
SSTRINGF | PosiPatch Flexible Magnetic Ring | $195.00 | ||
SSTABRKIT | Abrasives Test Kit | $490.00 | ||
SSTDISPTIP | Plastic Dispensing Tips(10) | $40.00 | ||
SSTNEEDLE | Hypodermic Needle (10) | $10.00 | ||
SSTSYRINGE3 | 3 ml Grad.Syringe (10) | $10.00 | ||
SSTCUP | 30 ml Grad. Cups (10) | $20.00 | ||
SSTSLTN84 | Conductivity Standard | $35.00 | ||
SSTDIWATER | Deionized Water 250 ml | $25.00 | ||
SSTSWAB | Foam Swab (5 pk) | $10.00 | ||
Pelican Inspection Case (large) | $370.00 |
In stock
1 Week Lead Time (Estimated)
2-3 Week Lead Time (Estimated)
Lead Time Varies, Please contact us for availability.
Unavailable